Unigas PTZ Compact Volume Converter / Electronic Compact Volume Converter |
|
Task :
The state volume converter UNIGAS PTZ converts the measured gas volume Vb of one gas meter at operation condition into m³ dry gas from standard condition pn = 1,01325 bar and Tn = 273,15 K.
The compressibility is considered as fixed value or acc. to the chart pressure stored in the calculator and temperature dependent.
Operating Principle :
The operation volume gas meter transmits impulses proportional to the measured flow to the processor of the UNIGAS PTZ Compact by means of a low frequency impulse converter mounted in or at the gas meter. The processor |
|
|
receives the values of the operation pressure and -temperature from the sensors, which are either installed directly at the gas meter or at the piping. |
|
|
Scope of delivery :
UNIGAS PTZ Compact consists of the micro-processor controlled computing device, the pressure- and the temperature sensors and an optimised 3-way test cock. The computing device can be mounted directly to the gas meter or separately and is certified for use in hazardous aereas according to (EEX ib IIC T5). |
|
Pressure ranges :
Pabs= 0,9 bar to 6,0 bar with official calibration "national"
Pabs= 4,0 bar to 10,0 bar with official calibration "national" |
|
| Temperature ranges : |
Gas temperatures -10°C to 40°C
Ambient temperature -10°C to 40°C
Storage temperatures -20°C to 50°C |
|
| Gas types : |
| Natural gas acc. to DVGW-worksheet G 260, technical gases. |
|
| Retrievable data : |
| Concerning the operation condition the UNIGAS PTZ Compact indicates the actual volume at standard condition via the LCD-display. By depression of key, the following values can be retrieved in addition: |
|
operation cubic meter Vb |
|
gas temperature in °C |
|
operation pressure pabs in bar |
|
condition indicator Z |
|
fault codes |
|
battery consumption in mAh |
|
operating hours |
|
fault register for Vn |
|
fault register for Vb |
|
compressibility factor K |
|
remote data transfer on request |
|
|
Accuracy :
Total errors of measurement (reproducibility, hysteresis, room temperature) within ± 0.5 % from measured value. |
|
Impulse output :
A standard m3 impulse output with pulse times of 10 ms, 30 ms, 40 ms or 100 ms is programmable. Furthermore, an actual m3-impulse output or a fault alarm output is also programmable. A data interface RS 232 is also available. |
| |