Units Delta Blower For Landfill And Biogas |
|
The positive displacement blower units DELTA BLOWER have been modified specially for applications in the range of landfill- and biogas as well as also natural - or town gas. Intake volume flow approx. 60 up to 2.500 m³/h. |
|
| Intake volume flow |
: |
approx. 60 up to 2.500 m³/h |
| Size |
: |
10 |
| Suitable for |
: |
landfill- and biogas as well as also natural - or town gas |
| Pressure operation |
: |
pressure differences up to 1.000 mbar |
| Suction operation |
: |
pressure differences up to -500 mbar |
|
|
| |
|
|
|
| Compression of bio / landfill gases and other non inert gases |
|
The specific utilization of bio – and landfill gases contributes to reduce the emissions of gases which are dangerous for the climate by generating power. In block-type thermal power stations (BHKW) current is produced in gas motor – generator aggregates. The waste heat arising during combustion is supplied via heat exchangers to a further utilization. Concerning gas exhaust and admission pressure production for block-type thermal power station and flare unit, gas compressors are used. Aerzen gas units are designed for the conveyance and compression of landfill - and biogas as well as natural - or town gas. The blowers can be operated with differential pressures up to 700 resp. 1000 mbar depending on blower size and intake pressure. |
|
| Standard - scope of supply |
|
Blower stage with gastight sealing of the driving shaft, (explosion-proof up to 12 bar with TÜV - certificate or strength test by a hydrostatic test with 5 bar), combined conveying chamber sealing for humid landfill gas (option), special corrosion protection-coating of the rotors and the conveying chamber (option). |
|
Base support with integrated discharge silencer dimensioned for operating overpressure 1 bar (explosion-proof 12 bar) |
|
Flexible machinery mountings with fixing bolts |
|
Hinged motor mounting plate as belt tensioning device |
|
Belt drive complete (narrow v-belts antistatic) |
|
Belt guard (spark-safe) (in case of design with acoustic hood hand guard) |
|
Suction silencer dimensioned for operating overpressure 0,1 / 1,0 bar (explosion-proof 12 bar) |
|
Non-return flap for installation between two flanges |
|
Axial compensators suction - and discharge side |
|
Starting strainer with intermediate ring |
|
Driving motor |
|
| Among others the following components are available in addition beside the described standard concept : |
|
Bypass operation with overflow regulator for keeping the discharge pressure |
|
Pressure protection via safety relief valve |
|
Bypass with start-up unloading device |
|
Purge gas station (admission of the neutral chambers with purge gas) |
|
Shut-off devices (e.g. ball cocks) |
|
Instrumentation and protection |
|
Acoustic hood |
|
| |
| Accessory components as option : |
|
Driving motor (three phase a.c. motor) |
|
Acoustic hood |
|
Start-up unloading device (necessary in case of star-delta-starting of the driving motor) |
|
Pressure gauge (for indication of the conveying pressure) |
|
Maintenance indicator (for monitoring of the intake filter) |
|
Switch cabinet |
|
| After arrangement special designs and modifications regarding design and material are possible. |
Acc. to EC-guideline 94/9/EC (ATEX) the units can be used within the appliance group II in category 2 with corresponding equipment – therefore zone 1 internal and external (temperature class T3). |
| |